Project:
Reverse osmosis 1800L/h with pre-treatment and post-treatment
Year: 2022
Location: Valencia
Scope: Design, manufacture, installation and commissioning.
Capacity: 1800L/h
Final water application: Drinking water
Source of water: Well water.
Description:
Pretreatment:
- Prechlorination Equipment
- Roughing filtration
- Dechlorinating filter
Reverse osmosis:
- 1 membrane rack to produce 1,8 m3/h
- Security microfiltration
- Raw water redox meter
- Raw water conductivity meter
- Permeate water conductivity meter
- Automatic Flushing System
- Electrical panel with Siemens PLC
Post-treatment:
- Remineralisation
- Post-chlorination with chlorine and pH control panel in recirculation.